A diesel tank that stays in one place and a tanker that pulls into the same unloading bay every day need different berms. For the tank, you need room to reach the outlet valve and connect a hose. For the tanker, you need to know which walls the vehicle can cross and where it will park during unloading.

A spill containment berm catches leaks from tanks, drums, vehicles and equipment before the liquid spreads across the floor or reaches nearby drains or soil. Before you order one, walk through the area and check where a spill could happen, how people and vehicles will move around it, and how much liquid the berm needs to hold.

1. Identify Where a Spill Could Happen

1.1 Storage areas – Look at where fuel tanks, drums and IBCs are kept. Note what each container holds and where the outlets, valves and fittings are located.

1.2 Transfer and unloading areas – Check where tankers park, where hoses connect and where liquid could drip when a hose is disconnected. Mark those points on a site sketch so you can check whether the berm covers them.

1.3 Maintenance areas – Look under pumps, hydraulic equipment and machinery that may leak during servicing. Check whether the equipment stays in place or needs to be moved in and out of the bay.

2. Choose the Right Type of Spill Containment Berm

2.1 L-bracket containment berm – Consider this for a stationary fuel tank, IBCs or drums. The brackets hold the walls upright and take up space outside the berm. If you’re setting it up beside a wall, fence or walkway, ask how much room the brackets need.

2.2 Foam wall spill berm – Consider this for a maintenance bay where low, flexible walls make equipment access easier. If a forklift needs to cross the wall, check that the model is suitable for its wheel loads and how often it will cross.

2.3 Drive-through containment berm – Consider this for a truck or tanker bay with regular vehicle traffic. If drivers enter at one end and leave at the other, confirm that both ends are designed for vehicle crossings. Share the vehicle dimensions, expected tyre loads and traffic direction when requesting a quote.

3. Check the Size and Spill Capacity

3.1 Measure the full setup – Include tank stands, pipes and fittings. Leave room for your team to reach valves and connect hoses. For a tanker bay, check where the unloading connection sits when the vehicle is parked.

3.2 Ask for the inside and outside dimensions – The inside measurements tell you whether your equipment fits. The outside measurements tell you how much space the berm and its supports will take up on site.

3.3 Confirm the required capacity in litres – Ask your site HSE team or project engineer how much liquid the berm needs to hold, then check that figure against the model’s rated capacity. For an outdoor installation, ask whether your project requires an allowance for rainwater.

4. Check the Liner and Ground Conditions

4.1 Tell the supplier what could spill – Name the liquid, whether it’s diesel, hydraulic oil or a specific chemical. For chemicals, share the safety data sheet and expected operating temperature so the supplier can check the liner material.

4.2 Describe the ground – Say whether the berm will sit on concrete, asphalt or compacted ground. If the surface is rough, ask about a ground pad. If vehicles will cross regularly, ask whether wheel-track protection is available for the model.

4.3 Mention how long the berm will stay outdoors – include the expected site temperature and whether the berm will sit in direct sun. These details help the supplier check which liner is suitable for the job.

5. Ordering a Spill Containment Berm in the GCC

KNZ Middle East supplies ENPAC spill containment berms across all six GCC countries, covering the UAE, Saudi Arabia, Oman, Qatar, Kuwait and Bahrain. If a standard berm won’t fit your site, we can arrange a custom size.

Contact KNZ Middle East for a quote with the tank or vehicle dimensions, liquid type, required containment capacity, delivery city and required date. A site photo or sketch is useful if space is tight or vehicles need to cross the berm.

Frequently Asked Questions

What type of spill containment berm can I use for a diesel tank?

For a stationary diesel tank, consider an L-bracket berm. Check that the liner is suitable for diesel, the berm meets your site’s capacity requirement and there is room to reach the tank fittings.

What’s the difference between a foam wall berm and a drive-through berm?

A foam wall berm has low, flexible sides. A drive-through berm has specific walls designed for vehicle crossings. Some drive-through models also use foam, so check which walls your vehicle can cross and what wheel loads the model can handle.

Can I order a custom-size spill containment berm?

Yes. Send KNZ the equipment dimensions, the space available and the required containment capacity. A simple sketch helps us see how much space you have.

Does KNZ supply spill containment berms across the GCC?

Yes. KNZ supplies the UAE, Saudi Arabia, Oman, Qatar, Kuwait and Bahrain. Share your delivery city and required date so we can confirm availability and lead time.

ENPAC 2 ft L-bracket spill containment bermENPAC Snap-Foam drive-through spill containment berm with a lowered entry wall.Black foam-wall spill containment berm with yellow corners.